Fencing & Guardrails
Double Wire Fence
Double wire fence panels use twin horizontal wires and vertical wires to improve rigidity for factories, schools, parks, warehouses and perimeter security projects. Buyers should confirm panel type, size, wire diameter, mesh opening, post system, coating and accessories before quotation.
Files PDF, DWG, DXF, sketches and product photos are welcome.
Buyer overview
Double Wire Fence Is Specified by Panel Type, Post Layout and Coating System
RFQs should confirm 656 or 868 panel type, panel height and width, mesh opening, wire diameter, post type, installation method, coating color, gates, clips, layout length and packing groups.
QY Metal Tech reviews layout drawings, site photos, panel schedule, accessory lists, quantity and export packing notes before quotation so panels, posts and clips match the installation sequence.
Panel type
Common 656 or 868 style can be reviewed by security and rigidity requirement.
Panel dimensions
Fence height, panel width and mesh opening should match the layout.
Wire and mesh
Horizontal twin wire, vertical wire diameter and mesh opening decide panel stiffness.
Posts and fixing
Post section, spacing, clips and base plate or embedded installation should be confirmed.
Coating and color
Galvanized, powder coated or PVC coated finish can follow project color.
Double wire fence panels: standard specifications
| Item | Common options | Notes |
|---|---|---|
| Panel type | 656: twin 6 mm horizontals + 5 mm verticals; 868: twin 8 mm horizontals + 6 mm verticals | 868 is the stiffer panel for higher security. |
| Mesh | 200 × 50 mm | |
| Panel height | 630, 830, 1030, 1230, 1430, 1630, 1830, 2030, 2230, 2430 mm | Other heights by drawing. |
| Panel width | 2500 mm | 2.03 × 2.50 m is a common panel. |
| Posts | Rectangular 60 × 40 or 80 × 60 mm, square 60 × 60 mm; wall 1.5–2.0 mm | Panels clamped with flat bars and bolts. |
| Finish | Galvanized + polyester powder coating; hot-dip galvanized to ISO 1461; PVC coated | Chosen by outdoor exposure and color. |
| Color | RAL 6005 green, RAL 7016 grey, RAL 9005 black or project color | |
| Installation | Posts set in concrete or fixed with base plates | Gates and corner posts supplied to the layout. |
Double Wire Fence Technical Reference
| Panel type | 656 or 868 panel typeSelect by rigidity, site security level and budget. |
|---|---|
| Panel dimensions | Panel height, width and mesh openingMatch the layout drawing and post spacing before quotation. |
| Wire and mesh | Horizontal and vertical wire diameterConfirm mesh opening for stiffness, visibility and security level. |
| Posts and fixing | Post section, fixing route and clipsConfirm base plate or embedded installation with bolts and corners. |
| Coating system | Galvanized, powder coated or PVC coated finishMatch outdoor exposure, project color and buyer documents. |
Design notes
Send the Fence Layout, Post Details and Accessory List
Fence height, panel width, mesh opening, wire diameter, post spacing, corner layout and gates usually decide whether the quotation can be prepared quickly.
For replacement or extension projects, site photos, old panel dimensions and marked layout sketches help confirm compatibility.
Standards reference
Fence Standards and Coating References Can Be Reviewed by Project Requirement
- Double wire fence systems can be reviewed by project drawings, panel schedule, site layout and local perimeter security requirements.
- 656 and 868 panel expressions should be checked by wire diameter, mesh opening, panel height and rigidity requirement before production.
- Hot-dip galvanizing, powder coating or PVC coating can be specified by outdoor exposure, color requirement and buyer documents.
- Final specification should follow approved layout drawings, post installation method, gates, accessories and packing marks.
Specification examples
Common Double Wire Fence Model Expressions
| 656 panel | Twin 6 mm horizontal wires + 5 mm vertical wireCommon rigid panel expression for 656 fence systems. |
|---|---|
| 868 panel | Twin 8 mm horizontal wires + 6 mm vertical wireStronger panel expression for higher perimeter rigidity. |
| 2.03 x 2.50 m panel | Common panel size referenceFinal height and width should follow the project layout. |
| Powder coated system | Panels, posts, clips and gatesSupply as one system with project color and accessories. |
Use these examples as RFQ shorthand, then confirm panel height, width, mesh opening, wire diameter, posts, coating, accessories and layout before production.
Applications
Where Double Wire Fence Is Commonly Used
Facility perimeter
Factories, warehouses, industrial parks and commercial sites.
Public and school fencing
Rigid panels for visible boundary protection around campuses, parks and public areas.
Fence system packages
Panels, posts, clips, gates and accessories can be quoted and packed together.
RFQ checklist
Send Double Wire Fence Panel and Post Details
For faster quotation support, include panel height, width, mesh opening, wire diameter, post type, spacing, coating color, gates, clips, quantity and destination. Layout drawings or marked site photos are useful when the fence must match an existing boundary.
Double Wire Fence RFQ checklist
- Panel height, width, wire diameter and mesh opening
- 656 or 868 panel type and required coating color
- Post type, spacing, base plate or embedded installation method
- Gates, clips, bolts, caps, corners and accessories
- Layout length, quantity, destination and packing marks
Project notes
Confirm Layout, Accessories and Packing Before Production
For project supply, double wire fence panels should be checked against the site layout, post spacing, corner and gate positions before production.
Clear panel marks, post groups, clip and bolt quantities, color requirement and packing notes reduce revision time and help installers sort materials on site.
Production and packing review
- Approved layout, panel marks and post group sequence
- Coating color, surface condition and accessory quantities
- Panels, posts, clips and gates packed by installation zone
- Bundle labels, destination marks and spare fastener notes
- Photos, packing list and loading details prepared before shipment
FAQ
Common Double Wire Fence Questions
What is a double wire fence?
A rigid welded panel with twin horizontal wires and single vertical wires, used for factories, schools, parks, warehouses and perimeter security.
What is the difference between 656 and 868 panels?
656 uses twin 6 mm horizontal wires with a 5 mm vertical wire; 868 uses twin 8 mm horizontals with a 6 mm vertical, giving a stiffer panel.
What panel size is common?
2.03 × 2.50 m is a common panel size reference; final height and width follow your site layout.
Which finishes are available?
Hot-dip galvanized, powder coated or PVC coated, in your project color.
How are posts fixed?
Posts are embedded in concrete or fixed with base plates. Post section, spacing, clips and bolts are confirmed with the layout.
Can you match panels for an existing fence?
Yes. Send site photos, old panel dimensions and a marked layout sketch so new panels and posts are compatible.
Related paths
Continue from this product
Need a Practical Double Wire Fence Quotation?
Include panel size, 656 or 868 type, mesh opening, wire diameter, post type, coating color, gates, clips, layout length, quantity and destination. We will review the details before quotation.
System specification
Double Wire Fence Panel, Post and Accessory Specification
A double wire fence inquiry should define the panel, horizontal and vertical wire arrangement, mesh opening, post and fixing system, coating, gates and complete site layout. A panel description alone does not define the installed fence system or the supply boundary.
Fence system fields to confirm
| Field | What to send |
|---|---|
| Site and layout | Total length, panel runs, corners, level changes, gate positions and marked layout. |
| Panel | Finished width and height, horizontal and vertical wire arrangement, wire diameter and mesh opening. |
| Posts | Post section, post spacing, embedded or base-plated fixing, cap and corner or end-post details. |
| Panel fixing | Clips, clamps, bolts, security fasteners and quantity per post or panel if specified. |
| Coating and color | Galvanized, coated or project-specified finish, color reference and environment. |
| Gates and transitions | Gate opening, leaf arrangement, frame, hinges, lock, adjacent posts and interface details. |
| Supply boundary | Panels only or panels, posts, clips, gates, fasteners, touch-up items and packing. |
| Quotation inputs | Quantity by type, packing marks, destination, drawings and required documents. |
Prepare the double wire fence RFQ details, compare welded mesh vs double wire fence, and use the panel, post and gate checklist. When the system scope is clear, send the layout and RFQ to QY.
QY reviews the submitted product, dimensions, quantity, finish, packing and destination before quotation. Site security performance, wind or foundation design, installation method and local compliance remain subject to the project engineer or approving authority.
Selection path
Specification, data and project references
1 · Check technical data
2 · See project references
3 · Datasheet and quotation
Order terms
- MOQ: 50 pcs (panels, rolls or pieces)
- Samples available; sample and freight costs paid by the buyer
- Payment: 30% deposit, 70% before shipment
- Lead time: usually 30 days ex-works after deposit and drawing approval
- Quotation in 24–48 hours on working days
- Drawings: PDF, DWG, DXF, JPG, PNG, WebP up to 12 MB
Product datasheet
Double Wire Fence (656 / 868) datasheet
2-page PDF: typical specifications, what we confirm before quotation, RFQ checklist and contact details. (481 KB)
RFQ form
Request Double Wire Fence quotation
Upload drawings or marked site photos if available. Include panel size, wire diameter, mesh opening, post type, coating, accessories, quantity and destination for a faster technical response.
Related links
Related product and RFQ resources
- Fencing and guardrails product catalogBrowse the related product family section.
- Fencing and guardrails topic entryFencing and guardrail product pages for highway guardrails, welded mesh fence, chain link fence, double wire fence, municipal guardrails and railings.
- Welded Mesh Fence RFQ Guide for Site Boundary ProjectsRFQ guide for welded mesh fence projects covering boundary use, panel size, wire diameter, mesh opening, posts, finish, gates, accessories, quantity and destination.
- Chain Link Fence vs Welded Mesh Fence for Site Boundary RFQsFence comparison and RFQ guide covering chain link fence, welded mesh fence, panel or roll form, posts, coating, gates, accessories, quantity and destination.
- Highway Guardrail RFQ Checklist for Road Safety ProjectsHighway guardrail RFQ checklist covering beam profile, beam length, post type, spacers or blockouts, bolts, terminals, finish, project standard, quantity, packing and destination.
- Send project RFQ detailsSend drawings, dimensions, finish notes, quantity and destination for review.
Factory verification and order terms
Video factory visits by appointment
Video factory visits can be arranged in advance. Contact our sales team to agree a time, platform and accessible production, inspection or packing areas. Other customers’ information and confidential areas are not shown.
Lead time: usually 30 days ex-works
For regular orders, production usually takes 30 days ex-works, counted from receipt of the deposit and approval of the drawings. Larger or special orders, and stock availability, are confirmed in the written quotation. Production and transport times are stated separately in the quotation or contract.
Written quotation and delivery terms
Trade terms are agreed for each order and logistics arrangement. The written quotation specifies the applicable Incoterms® 2020 rule, named delivery place or port of shipment, and whether freight, insurance and taxes are included. For containers handed to a carrier before vessel loading, FCA is considered rather than automatically using FOB.
Quality concerns and corrective action
Please provide the order number, affected quantity, photos or video, and relevant measurements or inspection records when reporting a quality concern. If responsibility is confirmed to lie with us, a remedy such as repair, additional supply, replacement, refund or price adjustment is agreed under the contract. Costs and the action plan are confirmed in writing; no unconditional return or fixed resolution period is promised.